A 2-line jet pump uses a venturi valve at the bottom of its pair of water pipes (water down one and more water up the other) to bring up water from the bottom of a well or from a pickup point in a lake or water tank.

Why does my pump keep losing prime?

If your foot valve is leaking your pump may lose its prime between starts. Debris blocking the suction strainer or foot valve is the most common cause. A blockage in the intake line can cause the water in the pump casing to overheat and literally boil out of the casing causing the pump to lose prime.

How do you prime a 2-line jet well pump?

To do this, shut the pump’s control valve after filling the pump casing and suction line with water. Run the pump, keeping its priming plug loose. This process gets rid of trapped air inside the pump. Repeat the process until smooth water flows around the prime plug, and precharge the pressure tank.

Are jet pumps self-priming?

Suitable for use with clean water and liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming FUTURE JET pumps are designed to pump water even in cases where air is present.

Why am I losing suction in my pool?

SUCTION LEAK AT PUMP (Low PSI) – The pump lid o-ring, pump intake fitting, and drain plugs are common areas to draw in air. A suction leak in the suction side of the pump can cause a number of problems. If it’s large enough, too much air will be sucked into the system, and the pump will lose prime.

How do you adjust a pressure regulator on a jet pump?

Turn on the power to the pump. Adjust the pressure switch’s high-limit adjustment screw with a 3/8-inch hex-head screwdriver. Turn the adjustment screw left, or counterclockwise, to reduce the pressure switch’s setting. The jet pump turns on once the water pressure drops to the set low limit.

Why does water pressure keep dropping?

There are two main problems that typically cause a loss of pressure – water escaping somewhere in the system or a failure of the expansion valve and resulting damage to the pressure relief valve.

Do jet pumps need to be primed?

Jet pumps are the most common pumps installed in shallow-depth residential water wells. The intake pipe must remained primed, filled with water at all times, in order to generate the suction that pulls water up out of the well and into the household water line.

How deep can a 2 line jet pump pump go?

A two-line jet pump can typically raise water from depths of 30-feet to 80-feet, and at water delivery rates of 4 gpm (gallons per minute) (for a 1/2 hp 2-line jet pump serving an 80 foot deep well) to 16 gpm (for a 1 hp 2-line jet pump serving a 30 foot deep well).

What happens if a 2 line jet pump loses its prime?

The requirement to have some water to send down to the well in order to bring a larger quantity of water back is why a two line jet pump can’t provide any water or water pressure in a building if it loses its prime. See WELL PUMP PRIMING PROCEDURE if you need to re-prime your jet pump.

What is the difference between a 1 line and 2 line pump?

Some 2-line jet pump systems, particularly for low yield wells, may add a tailpiece below the in-well jet assembly, going down as far as another 34 ft. Maximum pumping lift can be > 200 ft. depending on pump and other design details. A one line jet pump uses a single suction pipe to draw water from the well.

What is the maximum lift for a 1 line jet pump?

Maximum pumping lift is 15 ft. When you are buying a whole new 1 line jet pump to replace a 2-line jet pump system, most likely you’ll need to pull the well line to replace the 2-line tailpiece with a 1 line jet pump foot valve.