Common questions

What does ASTM E119 mean?

What does ASTM E119 mean?

Fire Tests of Building Construction
ASTM E119, Standard Test Method for Fire Tests of Building Construction and Materials, is. used to determine the fire resistance of a complete assembly. For example, a wall system fire.

What is the ASTM E119 test?

What is ASTM E119? ASTM E119 (UL 263): tests the fire resistance of an assembly. This test evaluates the duration for which building construction materials and assemblies can either contain a fire, retain structural integrity, or both.

What is the difference between UL 10b and UL 10c?

UL10B: Standard for Safety Fire Tests of Door Assemblies. UL10C: Standard for Positive Pressure Fire Tests of Door Assemblies.

What is ul9?

UL 9, 8th Edition, July 2, 2009 – UL Standard for Safety Fire Tests of Window Assemblies. These methods of fire tests are applicable to window assemblies, including glass block and other light transmitting assemblies, for use in the protection of openings in vertical fire resistive assemblies.

What is nfpa285?

In 1998, the National Fire Protection Agency (NFPA) developed a standard NFPA 285 which is a test method designed to determine the flammability characteristics of exterior, non-load-bearing wall assemblies/panels that contain foam plastic insulation. …

What is UL 10B?

UL 10B Fire Test of Door Assemblies(UL Approval)– scope. The tests expose a specimen to a standard fire exposure controlled to achieve specified temperatures throughout a specified time period, followed by the application of a specified standard fire hose stream.

What is the minimum rating for a UL door?

These products are investigated in accordance with UL 9, Standard for Fire Tests of Window Assemblies. These products are Classified for fire ratings of 3/4 hour, 1 hour, 1-1/2 hours, and 3 hours, or a fire rating of 20 min fire-protection rated without hose stream as indicated in the individual Classifications.

What does UL 10c mean?

“Standard for Positive Pressure Fire Tests of Door Assemblies.” The tests expose a specimen to a standard fire exposure controlled to achieve specified temperatures throughout a specified time period, followed by the application of a specified standard fire hose stream. …

What is a BS 8414 test?

BS 8414 – is a large-scale system test that mimics a fire breaking out of a window and exposing a cladding system to a severe fire.

What is ASTM e119-00a?

1American Society for Testing and Materials, 2000 Annual Book of Standards, ASTM E119-00a Standard Methods of FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS. Project No. 16235-117482 February 25, 2004 Panel Built Inc. Page 2

What is the ASTM D2344 test standard for laminated composites?

American Society for Testing and Materials (ASTM) [1] proposes two test standards: short beam shear (D2344) and double- notched shear (D3846-99) to measure ILSS of laminated polymeric composites. The four- point short beam shear test (ASTM D790) was also used in the literature.

What is interlaminar shear strength (ILSs)?

Interlaminar Shear Strength (ILSS) is an important material property for design of laminated composite structures subjected to transverse loads. American Society for Testing and Materials (ASTM) [1] proposes two test standards: short beam shear (D2344) and double- notched shear (D3846-99) to measure ILSS of laminated polymeric composites.

What is the astastm e119-00a fire test?

ASTM E119-00a Fire Tests of Building Construction and Materials Sandwich Panels For Modular Construction Project No. 16235-117482 ONE-HOUR FIRE RESISTANCE TEST OF A NON-BEARING WALL ASSEMBLY February 25, 2004 Prepared for: Panel Built Inc. P.O. Box 2658 Blairsville, GA 30514